DSC
Multiple Keypads
| four different keypads available |
| connect up to 8 keypads to a panel |
| PC5508 standard 8 zone LED keypad |
| PC5516 standard 16 zone LED keypad |
| PC5532 standard 32 zone LED keypad | |
| LCD5500 alphanumeric keypad |
| expand from 8 to 32 zones | |
| 2 partitions |
| PC5108 - 8 zone expansion module | |
| PC5108D - 16 zone expansion module utilizing zone doubling |
| PC5132-900- wireless zone expansion module | |
| connect up to 32 wireless zones |
| up to 4 high current outputs |
| PC5204 |
| 4 output high current power supply module | |
| 1 output fully supervised for siren output |
| up to 8 voltage outputs |
| PC5208 |
| 8 output transistor switch module (50 mA) |
| supports all major formats including SIA and Contact ID | |
| LINKS cellular communication | |
| event initiated personal paging | |
| 3 phone numbers, 2 account numbers |
| supports central station two way voice and home intercom features |
| 4 wire communications bus (KEYBUS) |
| - connect modules up to 1000' (330m) from control panel | |
| - up to 1.5A auxiliary power | |
| - PC5204 - 4 output high current supply module provides up to 1A auxiliary power | |
| - main panel provides up to 500mA auxiliary power |
| up to 32 fully programmable zones |
| 8 zones on main control panel (16 with zone doubler option) | |
| hard wire zones and wireless expansion | |
| all zones programmable as burglary or fire | |
| assign zones to one or both partitions | |
| zone options include: End Of Line (EOL) Resistor, Double EOL resistor, Normally closed loops or zone doubling. | |
| 24 programmable zone types |
| 2 partitions |
| most features programmable by partition | |
| 32 - 4 or 6 digit access codes assignable to one or both partitions | |
| 1 system master code, 2 partition master codes, and 2 duress codes |
| 128 event buffer |
| all events automatically stored with time and date stamp to buffer | |
| events can be printed on-site, viewed through the LCD keypad or DLS software alarm output |
| alarm output |
| bell output - 700mA @ 12Vdc, PTC protected | |
| additional supervised siren output using PC5204 power supply module, 1A @12Vdc, PTC protected |
| programmable voltage outputs |
| main panel PGM2 - high current switch to ground (can also be used for 2 wire smoke) | |
| main panel PGM1 - low current, 50mA@12Vdc | |
| additional low current voltage outputs using PC5208 output module, 50mA@12Vdc | |
| additional high current voltage outputs using PC5204 power supply module, 1.0A@12Vdc |
| upload/download capability |
| program system using DLS software | |
| view status and trouble conditions | |
| view 128 event buffer |
| power capability |
| 500mA@12.5Vdc (400mA for UL applications) | |
| separately fused battery and bell output | |
| positive temperature coefficient (PTC) AUX & Bell output protection | |
| electronic protection of KEYBUS | |
| supervision of AC power loss, low battery, auxiliary power failure |
| battery required |
| 12V, 4Ah, rechargeable gel-cell |
| transformer required |
| 16.5Vac, 40VA |
| up to 2 partitions |
| each partition acts as a separate alarm system with any number of zones, user codes, keypads and individually programmable features. |
| each partition can have any number of user codes which may be enabled to work on one or both partitions | |
| programmable system access by user code | |
| individual open/close reporting by user |
| each partition may be programmed to auto-arm at different times |
| allows users to arm and exit easily |
| security of perimeter arming while premise is occupied |
| programmable by zone | |
| monitor a door by having keypad beep when the door is opened and closed |
False Alarm Prevention Features
| audible exit delay | |
| audible exit failure | |
| programmable swinger shut down by zone | |
| programmable transmission delay by zone | |
| opening after alarm transmission |
Trouble conditions are displayed on all keypads and can also be communicated to central station for:
| low battery | |
| loss of AC | |
| auxiliary power failure | |
| zone tamper | |
| siren circuit trouble | |
| fire circuit trouble | |
| buffer near full capacity | |
| failure to communicate | |
| telephone line trouble (via Links cellular communicator) | |
| KEYBUS module communication failure | |
| PC5204 power supply module low battery | |
| PC5204 power supply module AC power loss |
Plain Language Interfaces
LCD5500 Keypad
The Power 832 security system is fully programmable from the attractive, easy to use multi-language LCD5500 keypad:
| multi-language : English, French, Spanish |
| simple key entry to toggle between languages while viewing keypad |
| zone identification | |
| system instructions | |
| system status | |
| 128 event buffer | |
| trouble conditions |
| menu for user functions | |
| what key to press for specific functions | |
| steps for programming functions |
| allows system status to be viewed at a glance |
| display and keys backlit for easy viewing in low light conditions |
| provides audible feedback for correct key entries, pre-alert, and system trouble status |
| current draw - 50mA | |
| dimensions - 5.75" x 4.5" x 1" deep (144 x 114 x 25mm) |
LED Keypads
The Power 832 system is fully programmable from any of the attractive, easy to use, LED keypads:
| 8 zone, 16 zone and 32 zone keypads | |
| keypads have 5 programmable function keys with 18 options such as home arm, away arm, quick exit, etc. | |
| connect up to 8 keypads, combination LED and/or LCD | |
| any keypad can be assigned as 'Global' for system wide control or 'Partition' for specific partition only | |
| 3 LED indicators: Ready, Armed, Status |
| allows system status to be viewed at a glance |
| provides audible feedback for correct key entries, pre-alert, and system trouble status |
ESCORT 5580 Voice Prompt
Module with Automation/Lighting Control
| turns any touch-tone phone into a fully functional keypad | |
| built-in power line interface for X-10 control devices | |
| connect up to 32 X-10 devices | |
| options include - 'Global' or 'Partition' control | |
| 16 schedules, 8 modes | |
| customized commands | |
| module contains extensive library of voice prompts |
| program up to 6 words per label | |
| 180 pre-programmed system words | |
| 241 pre-programmed library words |
PC5901
. . . internal intercom station
| PC5908 Audio Interface Module |
| provides 7 output ports for connection of PC5901 Series Intercom Stations |
| page/answer - do not disturb | |
| doorbell function |
| supports call waiting | |
| allows call transfer to in-house phones |
| provides plain language prompts for system programming, operation, and system status reports when installed with Escort 5580 Voice Prompt Module and Keypads mounted with PC5901 Intercom Stations |
| programmable control tones (from central station) | |
| select zone, listen/talk, extend on-line time, hang up |
| allows serial printer connection for report of events logged to the PC5010 event buffer | |
| supports any 300, 1200, 2400 or 4800 BPS serial printer | |
| multiple connects up to 4 wire KEYBUS up to 1000' (330m) from control panel | |
| c/w DB-25 modular connector for easy connection | |
| current draw : 30mA | |
| maximum one module per station |
| connect modules up to 1000' (330m) from control panel via KEYBUS | |
| assign zones to one or both partitions | |
| 25 programmable zone types |
| connect modules up to 1000' (330m) from control panel via KEYBUS | |
| connect up to 32 Marquis devices | |
| true 'Spread Spectrum' technology, 900MHz, fully supervised for communication integrity | |
| 12 minute supervisory time | |
| easy sensor enroll process | |
| standard AA/AAA alkaline batteries, 24 to 36 month life |
| provides 1A @ 12.5 Vdc for additional modules, device and siren outputs | |
| includes 4 fully programmable high current outputs |
| rated at 1A @ 12Vdc, PTC protected |
| module provides 8 low current transistor switch outputs |
| rated at 50mA @ 12.5Vdc |
The contractor shall provide a complete electrically supervised, battery backed-up, fire and burglary alarm system. The system shall be complete with a multi-zone alarm system with the capability of expansion up to 32 burglar or class B fire zones of which up to 32 may be wireless zones. All zones shall be supervised and be capable of operating listed heat detectors, smoke detectors and other listed fire and burglary alarm detection devices. The system shall have expansion capability for up to eight low current transistor switch outputs; and 4 high current outputs of which one may be fully supervised for an additional siren. All outputs shall be programmable as 1 of 18 types. System shall be complete with a 4 wire unshielded (QUAD) communications bus that allows expansion modules for zones and outputs to be added anywhere on the bus up to 1000' (330m) per leg from the main control panel. The system shall be capable of providing up to 1.5 amps of 12.5Vdc auxiliary power for alarm devices.
The system shall be complete with a built-in power line interface for up to 32 X-10 control devices.
The alarm panel shall be complete with an integrated digital communicator capable of being programmed to transmit to three separate monitoring stations or locations with 2 account numbers. The communicator shall be capable of supervising the telephone line; and shall support and supervise LINKS cellular communication with three telephone numbers for backup or sole communications to monitoring stations and for upload download operations. The system communicator shall be capable of communicating in all major formats including SIA and Contact ID. Events transmitted shall be programmable to include: fire alarms, burglary alarms, trouble alarms, supervisory conditions, alarm restoral codes, opening (disarming) and closing (arming) codes, partial closing codes, and opening after alarm codes. The system shall be capable of paging personnel on the occurrence of any of the above events selected by the owner. The system shall be capable of transmitting a test code to the monitoring station(s) on a programmable daily, weekly, or monthly frequency at a regular time of day.
The system shall be complete with audio interface capable of supporting up to 7 audio ports for local intercom/paging, listen-in broadcast, telephone answering, audio user help, and 2-way listen-in by the monitoring station.
There shall be a 700mA, PTC protected, supervised bell/siren circuit that will drive a bell/siren until reset or silenced. Siren output shall be programmable as steady or pulsed for each zone.
The alarm shall be equipped with EEPROM memory to retain all program information even if all AC and battery power is lost and shall have integral static and lighting protection circuitry.
The alarm panel shall have SIA false alarm prevention features, programmable swinger shut down by zone, programmable transmission delay buy zone, audible exit delay, audible exit fault, opening after alarm reporting, and 'quick exit' to prevent false alarms and unnecessary transmissions to monitoring stations.
The system shall allow up to 2 'partitions' each acting as a separate alarm system with its own zones, siren output, user codes and keypads for programming, arming and disarming. Each partition shall be programmable to Auto-Arm at different times on every day of the week.
The system shall have home-away and at-home arming capability to allow the user to remain on the premises while system is armed. A quick-arm feature shall allow users without access codes to arm the system and exit. A door chime feature shall cause the keypad to beep when a selected door in a partition is opened or secured.
The system shall support any combination of up to 8 "Multi-Language" or "LED" type keypads with backlit displays. Keypads shall be surface mounted and capable of fully programming and operating the system. Each keypad shall be assignable to operate the entire system or an individual partition. Multi-Language keypads shall be complete with 32 character liquid crystal display (LCD) to provide plain language programming instructions, operating instructions and display of all alarms and supervisory conditions. They shall be capable of toggling between English, French and Spanish by pressing a key combination on keypad. LED keypads shall have 6, 16 or 32 zone indicators as required. All keypads shall have keypad activated emergency alarms for panic, emergency, fire and duress; LED indicators for Ready, Armed and Trouble or Status; and shall be equipped with a Piezo Buzzer to provide audible feedback for correct key entries, pre-alert, and trouble.
The system shall allow any touch-tone phone to be used as a keypad with programmable voice prompts for system commands, functions, and labels (zones, etc.)
The system shall allow 32 - 4 or 6 digit - user codes which may be assigned to one or multiple partitions. The system shall accommodate 1-system master code, 2-partition master codes, and 2-duress codes.
The system shall be uploadable/downloadable to allow programming and operation from a remote computer over a telephone line or LINKS cellular communications equipment. Remote access shall be controlled by the owner to prevent unauthorized access.
The system shall support a 300, 1200, 2400 or 4800 baud serial printer connected to the communications BUS up to 1000' (330m) from the control panel. The printer shall log all system events and transactions with time and date stamp. Information shall be stored in the systems 128 event buffer which may be examined from the LCD keypad or the DLS software.
The system shall meet UL standards
as required for type of application.